BENDIX SD-03-10433 Fascicule

Page de 2
1
Bendix
®
 FCS-9700
™ 
Fan Clutch Solenoid
SD-03-10433
DESCRIPTION
The Bendix
®
 FCS-9700
 fan clutch solenoid, shown in 
Figure 1, is a low air fl ow solenoid used to control the fan 
clutch. A thermostat controls the solenoid operation.
The fan clutch solenoid is always mounted as a stand 
alone solenoid.  Depending on the application, it can be a 
normally closed (NC) or normally open solenoid (NO). The 
integral mounting bracket comes in a right or left position 
and is not removable.
OPERATION
Because this solenoid valve is used for an auxiliary air 
function, a pressure protection valve, such as a Bendix
®
 
PR-3
™ 
valve, must be installed to protect the air brake 
system.  Based on the application, the solenoid will 
deliver or exhaust air.  See Figure 2 for a typical system 
confi guration.
PREVENTIVE MAINTENANCE
Important:  Review the Bendix Warranty Policy before 
performing any intrusive maintenance procedures. The 
warranty may be voided if intrusive maintenance is 
performed during the warranty period.
DELIVERY 
PORT
SUPPLY PORT
FIGURE 1 - BENDIX
®
 FCS-9700
 FAN CLUTCH SOLENOID VALVES
EXHAUST 
PORT 
MOUNTING 
BRACKET 
(LEFT HAND)
ELECTRICAL 
CONNECTOR
No two vehicles operate under identical conditions; as 
a result, maintenance intervals may vary. Experience is 
a valuable guide in determining the best maintenance 
interval for air brake system components. At a minimum, 
the solenoid should be inspected every 6 months or 
1500 operating hours, whichever comes fi rst, for proper 
operation. Should the solenoid not meet the elements 
of the operational tests noted in this document, further 
investigation and service of the valve may be required.
SERVICE CHECKS
When the in-cab switch is pressed to activate or deactivate 
the fan clutch, the Bendix FCS-9700
 
solenoid will promptly 
exhaust (NO) or apply (NC).  Note that the solenoid part 
number label is marked with an NO or NC for identifi cation.  
Continuous exhausting of air pressure should not occur.
LEAKAGE CHECKS
With the air system fully charged, coat the exhaust ports 
of the solenoid with a soap solution.  A 1-inch bubble in 
three (3) seconds is permitted (175 SCCM).
EXHAUST 
PORT 
SUPPLY PORT
DELIVERY 
PORT
ELECTRICAL 
CONNECTOR
NORMALLY OPEN (NO) 
SOLENOID
NORMALLY CLOSED 
(NC) SOLENOID
MOUNTING 
BRACKET 
(LEFT HAND)