Beckett Burner F22 Fascicule

Page de 1
Features & Benefi ts
Available in either 12 Vdc or 24 Vdc confi gurations.
Beckett GeniSys Control uses a suitable cad cell 
fl ame sensor to control the motor, igniter, and 
solenoid valve.
Interrupted duty ignition extends battery life by 
only drawing full load current during the ignition 
period.  Intermittent duty ignition is also available.
Available with a pump-mounted solenoid blocking 
valve for smoother light-offs and cleaner shutdown.
Description
The Beckett SDC Oil Burner is designed for applications 
where an AC power source is not an option.  Available 
in 12 Vdc and 24 Vdc confi gurations, the SDC burner 
is conveniently powered by a standard direct current 
power supply.
 
Specifi cations
Electrical Ratings
Rated Voltage: 13.5V or 27V (Nominal Charging System Voltage)
Reference Voltage: 12V or 24V (Battery Discharge Voltage)
Capacity at Rated Voltage
1.75 - 5.50 GPH
245,000 - 770,000 Btu/h
Capacity at Reference Voltage
1.75 - 5.00 GPH
245,000 - 700,000 Btu/h
Fuels
No.1 or No.2 heating oil (ASTM D396) only
Dimensions
Height: 13-5/8”
Width: 15-3/8”
Depth: 8-1/2” (chassis only)
Ambient Operating Temperature
Min: +32°F (0°C)
Max: +115°F (46°C)





Power Supply
13.5 Vdc
27 Vdc
    Voltage range
11V - 16V
21.6V - 28V
Operating Load
25A max.
15A max.
    w/ igniter off
14 - 18 Amps
10 - 12 Amps
Motor Voltage, nominal
13.5V
27V
    Full load amps
20A max.
10A max.
    Locked rotor amps
100A
50A
Flame Retention Heads
SDC
 
Oil Burner
12 Vdc
 
or
 
24 Vdc
F22
1.75 - 3.25 GPH
F31
2.50 - 5.50 GPH
Product Sheet 
Form No. 61084 R01, Printed in the USA
 10/10