17 Keyboard Operation
17.1 General
Primary operation of an Allegiant switcher is controlled via the system keyboard. 
The two types of keyboards currently available are:
Conventional LTC 8555 Series (incorporates LEDs and pushbuttons).
IntuiKey model (uses dynamic LCD menu screens).
General operation steps for both keyboard models follows. Refer to the individual 
instruction manuals supplied with the keyboard for additional information. 
As the system is supplied from the factory, various user selectable features are set 
to a default state. See Chapter 14, “Factory Default Settings,” on page 50 for com-
plete feature descriptions. Since these features are user selectable and can have a 
significant effect on the operation of the system, it is important to take note of any 
changes that may be in effect.
17.2 System Commands
17.2.1 Keyboard Log-in Procedure
Keyboard modes:
Factory default, a keyboard is ready for use as soon as power is applied to the 
system.
System operator must log-on to a keyboard to access the system. When a sys-
tem is configured to use the keyboard log-on, operators must be pre-assigned a 
user number and password. Up to 32 user numbers are available, each having 
default priority level. User specific priority levels can be changed only via the 
optional PC-based LTC 8059/00 MCS package or the LTC 8850/00 GUI Soft-
ware. Refer to the software manual for complete details. 
If the log-on feature is enabled and an operator is not logged-in, LED keyboards 
show flashing dashes in their display. IntuiKey keyboards prompt for entry of a user 
number when attempting to enter the main Allegiant softscreen menu.
Enter your assigned user number via the numeric keypad and press 
[Enter]. When 
prompted, enter the password. Invalid passwords cause the keyboard to revert to 
its initial state. Once the log-in is successful, the keyboard will show camera and 
monitor numbers in its display. 
Upon logging in, the monitor controlled by the keyboard may automatically switch to 
a pre-assigned camera number. This function is only applicable if enabled by the 
system administrator (via the optional MCS package) and may not function if the 
monitor is running a sequence and/or in an alarm condition. 
NOTE
The information below applies to both IntuiKey keyboards and the LTC 8555 Series 
keyboards. Where applicable, button designations specific to IntuiKey keyboards 
are shown in plain text. Equivalent button designations that apply to the LTC 8555 
Series keyboards are placed in brackets ([ ]) immediately after the IntuiKey button 
text.