White Rodgers 36C01-405 Gas Valve Catalogue

Page de 1
36C Series
PARTS AND ACCESSORIES 
See end of this section for parts and accessories
36C SERIES
GAS VALVES
GAS BURNER
CONTROLS
?
WIRING 
172–175
HSI/DSI VALVES, INTERMITTANT IGNITION
36C74-913
Step
Open
24VAC Natural
3
/
4
 x 
3
/
4
Step
0.9”/3.5” 2.5”-5.0”
No
No
No
Str. Thru
Yes
Yes
No
5
36C94-303
Intermit-
tent
Ignition
Systems
24VAC Natural
or
LP
1
/
2
 x 
3
/
4
Delay
Slow
3.5”
2.5”-5.0”
7.0”-12.0”
Yes
Yes
No
Str. Thru
No
Yes
No
15
 Wiring diagrams – see pages 172–175 
 
 Indicates Canadian Model Number 
 
U
 =  
Universal
 
36C SERIES STANDING PILOT SNAP OPEN, STEP 
OPEN, HSI, DSI, AND INTERMITTENT IGNITION  
GAS VALVES
A Wide Range of Replacement Valves for the Professional Installer
SPECIFICATIONS
Electrical Rating . . . . . . . . . . . . . . . . . . . . . . . .   0.23 amps
Ambient Operating Range  . . . . . . . . . . . . . . . .   -40 to +175°F (-40 to 79°C)
Maximum Pressure Rating . . . . . . . . . . . . . . . .  
1
/
2
 PSI (14.0” W.C.)
Pilot Gas Connection  . . . . . . . . . . . . . . . . . . . .  
1
/
4
compression fitting
Pressure Tap  . . . . . . . . . . . . . . . . . . . . . . . . . .  
1
/
8
 N.P.T.
Pipe Size
1” Pressure Drop Capacity
Rated Range of Regulation
BTU/HR
BTU/HR
STD. NAT GAS
1000 BTU/CU. FT.
LP GAS
2500 BTU/CU. FT.
STD. NAT GAS
1000 BTU/CU. FT.
LP GAS
2500 BTU/CU. FT.
1/2 X 3/8
100,000
162,000
15,000-100,000
15,000-162,000
1/2 X 1/2
230,000
372,600
30,000-290,000
30,000-469,000
1/2 X 3/4
230,000
372,600
30,000-290,000
30,000-469,000
3/4 X 3/4
280,000
453,600
50,000-400,000
50,000-648,000
SNAP OPEN, SINGLE FUNCTION, STANDING PILOT GAS VALVES
Model
Number
Typical
App.
Coil
Voltage
Gas
Type
Pipe
Size
Opening
Character-
istic
Regulator 
Setting
Regulator 
Adjustment 
Range
Convertible
Nat. / LP
LP 
Conversion 
Kit Included
Line 
Interrupter
Flow
Direction
Reducer
Bushing
Kit
Inlet 
Pressure 
Tap
Side
Taps
Internal 
Wiring See 
Figure 
36C01-405 Snap
Open
24VAC Natural
or
LP
3
/
4
 x 
3
/
4
Fast Open
3.5”
2.5”-5.0”
Yes
Yes
No
Str. Thru
Yes
No
No
1
36C01A-405 Snap
Open
120VAC Natural
or
LP
3
/
4
 x 
3
/
4
Fast Open
3.5”
2.5”-5.0”
Yes
Yes
No
Str. Thru
Yes
No
No
3
36C03-300
Standing
Pilot
24VAC Natural
or
LP
1
/
2
 x 
3
/
4
Fast Open
3.5”
2.5”-5.0”
Yes
Yes
Yes
Str. Thru
Yes
No
No
1
36C03-333
Standing
Pilot
24VAC Natural
or
LP
1
/
2
 x 
3
/
4
Fast Open
3.5”
2.5”-5.0”
Yes
Yes
Yes
Str. Thru
Yes
No
Yes
1
36C03-400
Standing
Pilot
24VAC Natural
or
LP
3
/
4
 x 
3
/
4
Fast Open
3.5”
2.5”-5.0”
Yes
Yes
Yes
Str. Thru
Yes
No
No
1
36C03-433
Standing
Pilot
24VAC Natural
or
LP
3
/
4
 x 
3
/
4
Fast Open
3.5”
2.5”-5.0”
Yes
Yes
Yes
Str. Thru
Yes
Yes
Yes
1
36C03A-410
Standing
Pilot
120VAC Natural
or
LP
3
/
4
 x 
3
/
4
Fast Open
3.5”
2.5”-5.0”
Yes
Yes
Yes
Str. Thru
Yes
No
No
3
36C03U-333
Standing
Pilot
750mV Natural
or
LP
1
/
2
 x 
3
/
4
Fast Open
3.5”
2.5”-5.0”
Yes
Yes
Yes
Str. Thru
Yes
Yes
Yes
2
36C03U-433
Standing
Pilot
750mV Natural
or
LP
3
/
4
 x 
3
/
4
Fast Open
3.5”
2.5”-5.0”
Yes
Yes
Yes
Str. Thru
Yes
Yes
Yes
2
36C04U-438
Standing
Pilot
750mV Natural
or
LP
3
/
4
 x 
3
/
4
Step Open
0.7"
0.7 / 3.5” 2.5”-5.0”
No
No
Yes
Str. Thru
Yes
No
No
2
36C53-418
Standing
Pilot
24VAC Natural
or
LP
3
/
4
 x 
3
/
4
Slow Open
3.5”
2.5”-5.0”
Yes
No
Yes
Str. Thru
Yes
No
No
1
36C03-258
Standing
Pilot
24VAC Natural
or
LP
1
/
2
 x 
1
/
2
Fast Open
3.5”
2.5”-5.0”
No
No
Yes
Str. Thru
No
Yes
No
1
U
U
www.white-rodgers.com
38
HEA
TING