White Rodgers 21V51U-843 Universal Two-stage HSI Integrated Furnace Control Kit Schéma

Page de 2
INTEGRATED
FURNACE CONTROLS
21V51U-843 WIRING 
AND CONFIGURATION
The 50V51-843 has only one serviceable part –an automotive 
type fuse, which protects the low voltage transformer from dam-
age if the output is short-circuited. If the fuse has opened up, 
remove whatever caused the short circuit and replace the fuse 
with only a 3 amp automotive type fuse. If the fuse is not the 
cause of the control’s problem, replace the entire 50V51-843
control. There are no other user serviceable parts. 
Following installation or replacement, follow appliance manu-
facturer’s recommended installation or service instructions to
insure proper operation.
Y
W1
W2
G
R
O
B/C
DEHUM
YLO
R
G
W2
W1
Y2
Y
THERMOSTAT
50V51-843 TYPICAL SYSTEM WIRING DIAGRAM
Low Voltage (24 VAC)
Line Voltage (120 VAC)
LEGEND
N.C. = Normally closed switch
N.O. = Normally closed switch
HOT
(LINE)
NEUTRAL
(LINE)
120 VAC
24 VAC CLASS II
TRANSFORMER
50V51-843
24 VAC
TH
TR
LINE
XFMR
EAC
HUM
CIRC N
HUM N
LINE N
XFMR N
EAC N
E2
INDUCER
HUMIDIFIER
(OPTIONAL)
ELECTRONIC
AIR CLEANER
(OPTIONAL)
CONDENSING
UNITS
IGNITOR
IGN
IND HI
IND LO
IND N
IGN N
FLAME
SENSOR
PROBE
2ND STAGE PRESSURE
SWITCH (N. O.)
HIGH LIMIT
(N. C.)
AUX. HIGH
LIMIT (N. C.)
1ST STAGE PRESSURE
SWITCH (N. O.)
GAS
VALVE
HLO
HLI
FP
PS1
MVL
MVH
GND
GND
PS2
MV COM
TR
TH
ROLLOUT
SWITCH (N. C.)
CIRCULATOR
CIRC.
INTER-
FACE
www.white-rodgers.com
181
TECHNICAL