Whirlpool W10325493A Manuel D’Utilisation

Page de 32
13
Pilot and Bypass Screws Conversion
1. Remove control knobs and set aside.
2. Remove upper grates.
3. Lift the cooktop by both front corners until the side support 
rods snap into position.
4. Open oven door.
5. Locate the two top fasteners and two bottom fasteners and 
remove them using a Phillips head screwdriver.
6. Set the front panel aside and locate the oven thermostat.
7. Locate the LP gas bypass screw in the bag containing 
literature included with the range. One LP gas bypass screw 
is stamped “48.”
8. Remove the Natural gas bypass screw with a flat-blade 
screwdriver, turning counterclockwise.
9. Install the LP gas bypass screw with a flat-blade screwdriver, 
turning clockwise.
10. Locate the LP gas pilot screw in the bag containing literature 
included with the range. One LP gas pilot screw is 
stamped “15.”
11. Remove Natural gas pilot screw with a flat-blade screwdriver, 
turner counterclockwise.
12. Install the LP gas pilot screw with a flat-blade screwdriver, 
turning clockwise.
13. Replace the front panel and screw bottom and top fasteners 
in place.
14. Replace the control knobs. Push back on the side support 
rods and slowly lower the cooktop until it snaps into position. 
Close the oven door.
Complete Conversion
1. Refer to the “Make Gas Connection” section for properly 
connecting the range to the gas supply.
2. Turn the manual shutoff valve in the gas supply line to the 
open position.
3. Refer to the “Check Operation” section for proper burner 
ignition, operation and burner flame adjustments.
IMPORTANT: You may have to adjust the “LO” setting for 
each cooktop burner.
Checking for proper cooktop and oven burner flames is very 
important. The small inner cone should have a very distinct 
blue flame ¼" to ½" (0.64 cm to 1.3 cm) long. The outer cone 
is not as distinct as the inner cone. LP gas flames have a 
slightly yellow tip.
4. Close the broiler door and turn the knob to “OFF.”
5. Refer to the “Complete Installation” section to complete this 
procedure.
Natural Gas Conversion
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the “closed” position.
2. Remove grates.
3. Lift the cooktop by both front corners until the side support 
rods snap into position.
A. Top fasteners
B. Bottom fasteners
A. Oven thermostat
A. Pilot screw
B. Bypass screw
A
B
A
A
B
A. To range
B. Manual shutoff valve “closed” position
C. Gas supply line
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death 
or serious burns to children and adults.
A
B
C