WHP Wireless DL360 Manuel D’Utilisation
Troubleshooting
159
Description: The number of cache lines experiencing excessive ECC errors has
reached a preset limit. Therefore, the cache has been shut down.
reached a preset limit. Therefore, the cache has been shut down.
Action:
1. Reseat the cache to the controller.
2. If the problem persists, replace the cache.
Accelerator Status: Obsolete Data Detected
Description: During reset initialization, obsolete data was found in the cache due
to the drives being moved and written to by another controller.
to the drives being moved and written to by another controller.
Action: No action is required. The controller either writes the data to the drives
or discards the data completely.
or discards the data completely.
Accelerator Status: Obsolete Data was Discarded
Description: During reset initialization, obsolete data was found in the cache,
and was discarded (not written to the drives).
and was discarded (not written to the drives).
Action: No action is required.
Accelerator Status: Obsolete Data was Flushed (Written) to Drives
Description: During reset initialization, obsolete data was found in the cache.
The obsolete data was written to the drives, but newer data may have been
overwritten.
The obsolete data was written to the drives, but newer data may have been
overwritten.
Action: If newer data was overwritten, you may need to restore newer data;
otherwise, normal operation should continue.
otherwise, normal operation should continue.
Accelerator Status: Permanently Disabled
Description: Array accelerator board has been permanently disabled. It will
remain disabled until it is reinitialized using ACU.
remain disabled until it is reinitialized using ACU.
Action: Check the Disable Code field. Run ACU to reinitialize the array
accelerator board.