Installation
CR/EN (1004) 4.0
5 When the grout has thoroughly hardened, check the base plate bolt nuts and tighten 
if necessary.
3.5
Piping
• The piping to the suction and delivery connections must fit exactly and must not be 
subject to stress during operation. For the maximum allowable forces and moments on 
the pump flanges see paragraph 10.2 "Permissible forces and moments on the 
flanges".
• The passage of the suction pipe must be amply dimensioned. This pipe should be as 
short as possible and run towards the pump in such a way that no air pockets can 
arise. If this is not possible, a venting facility should be provided at the highest point of 
the pipe. If the inside diameter of the suction pipe is larger than the suction connection 
of the pump, an eccentric reducer should be applied to prevent air pockets and whirls. 
See figure 5.
• The maximum allowable system pressure is stated in paragraph 2.13 "Application 
area". If there is a risk that this pressure might be exceeded, for instance because of 
an excessive inlet pressure, appropriate measures should be taken by mounting a 
safety valve in the piping.
1 Drain  pan.
2 Wooden frame.
3 Shims.
4 Basic foundation.
5 Grout.
Figure 4:
Grouting base plate.
Figure 5:
Eccentric reducer to suction flange.
1
2
3
4
5
5