SPX Cooling Technologies Johnson Pump CombiPro Heavy duty access pump API 610 Manuel D’Utilisation

Page de 68
CR/EN (1004) 4.0
Disassembly and assembly
31
CombiPro
7 Disassembly and assembly
7.1
Precautionary measures
Take adequate measures to avoid that the motor is started while you are 
working on the pump. This is especially important for electric motors with 
remote control: 
• Switch the operating switch near the pump (if available) to "OFF".
• Switch off the pump switch on the switchboard.
• If necessary remove the fuses.
• Hang a danger board near the switchboard cabinet.
7.2
Special tools
Assembly and disassembly work requires no special tools. However, such tools can 
make certain jobs easier, for instance replacing the shaft seal. If such is the case it will be 
indicated in the text.
7.3
Draining
 !
Make sure no liquid or oil gets into the environment!
7.3.1
Liquid draining
Before starting any disassembly the pump should be drained.
1 If necessary, close the valves in the suction and delivery pipe and in the flushing or 
cooling supply lines to the shaft seal.
2 Remove the blind flange (1930). 
3 If harmful liquids are pumped wear protective gloves, shoes, glasses, etc., and 
thoroughly flush the pump.
4 Refit the blind flange.
7.3.2
Oil draining
If the pump is designed with oil lubricated bearings:
1 Remove the magnetic drain plug (2150).
2 Drain the oil.
3 Refit the magnetic drain plug.
If possible, wear protective gloves. Regular contact with oil products may 
result in allergic reactions.