ZyXEL NSA325 Manuel D’Utilisation

Page de 535
Chapter 17 Maintenance Screens
Media Server User’s Guide
312
Click Maintenance > Power to display the following screen.
Figure 186   
Maintenance > Power 
The following table describes the labels in this screen.
 
Table 108   
Maintenance > Power 
LABEL
DESCRIPTION
Power Management
Turn off hard 
disk(s)
Enter the number of minutes the NSA will sit idle before spinning the hard disks down to 
sleep. The default power-off time is 15 minutes.
Minimum UPS Capacity
Minimum UPS 
Capacity
When you use an APC Uninterruptible Power Supply (UPS) with a USB connection to the 
NSA, the NSA shuts itself down if the APC UPS’s battery charge gets down to the 
percentage you specify in this field. This allows the NSA to shut down properly and avoid 
data loss caused by a power failure when the UPS stops supplying power.
A setting around 50% is recommended. A setting close to 100% is not recommended since 
it would cause the NSA to shut down whenever the UPS is charging. A setting close to 0 is 
also not recommended since the UPS would not have enough power to allow the NSA to 
shutdown properly.
Power On After 
Power Failure
Select an option to set whether or not the NSA restarts when the power is restored after a 
power failure.
Keep Former 
Status
Select this option to have the NSA automatically restart only if it was operating when the 
power failed. The NSA remains off if it was already off when the power failed. 
Always Power On Select this option to keep the NSA operating as much of the time as possible. The NSA 
restarts automatically even if it was turned off when the power failed.