VXi VT1422A Manuel D’Utilisation

Page de 529
Specifications   451
Half Bridge Bending Errors: 
(5 V Excitation, GF=2)
μ
-50,000 
-40,000 
-30,000 
-20,000 
-10,000 

10,000 
20,000 
30,000 
40,000 
50,000 
Error (
μ
)
28
23
17
12
6
0.5
6
12
17
23
28
Full Bridge Bending Errors: 
(5 V Excitation, GF=2)
μ
-50,000 
-40,000 
-30,000 
-20,000 
-10,000 

10,000 
20,000 
30,000 
40,000 
50,000 
Error (
μ
)
28
22
17
11
6
0.3
6
11
17
22
28
Mechanical
Height: 
4.45 cm (1.75 in)
Width: 
49.53 cm (19.5 in)
Weight: 
1.8 kg (4 lbs)
Power Requirements
Line voltage: 100 - 240 V ac 
± 10% 
CAT II (2500 V
PEAK
 transients)
Line frequency: 
50 - 60 Hz
Input power: 
16 VA
Environmental
Pollution Degree: 
2
Temperature: 
-5 °C to +55 °C operating
Humidity: 
5 to 85% R.H.
Altitude: 
3,000 meters (10,000 ft) operating
10,000 meters (30,000 ft) non-operating
Warranty
VT1529A/B: 
3 year return to VXI Technology