Viking Technology Technology Computer Drive PSF1XXXXGXXXX Manuel D’Utilisation

Page de 60
 
 
 
Manual 
1/2/2014 
PSFS1XXXXGXXXX 
Viking Technology 
Revision B7 
 
Page 37 of 60 
www.vikingtechnology.com
 
 
addressed here. Further, it is recommended to consult the list of public 
S.M.A.R.T. attributes. 
 
5.1.8.1 
S.M.A.R.T. Command Set 
The supported S.M.A.R.T. command set is listed in the table below. See the AT 
Attachment standard for implementation details. 
 
Table 5-3: S.M.A.R.T. Command Set 
Value 
(hex) 
Command 
00-CF 
Reserved  
D0 
S.M.A.R.T. read attributes  
D1* 
S.M.A.R.T. read threshold  
D2 
S.M.A.R.T. enable/disable attribute autosave  
D3* 
S.M.A.R.T. save attribute values  
D4 
S.M.A.R.T. execute off-line immediate  
D5 
S.M.A.R.T. read log sector  
D6 
S.M.A.R.T. write log sector  
D7* 
S.M.A.R.T. write attribute threshold  
D8 
S.M.A.R.T. enable operations  
D9 
S.M.A.R.T. disable operations  
DA 
S.M.A.R.T. return status  
DB 
S.M.A.R.T. enable/disable automatic off-line  
DC-FF 
Reserved (Vendor Specific)  
* Note that D1, D3, and D7 have been made obsolete in the 
ATA-8 specification. 
 
5.1.8.2 
Off-line Mode 
The Element SSD supports the optional 28-bit S.M.A.R.T. EXECUTION OFF-
LINE IMMEDIATE (B0h/D4h) command per the ATA-8 specification. This 
command causes the Element SSD to initiate the collection of S.M.A.R.T. data in 
an off-line mode and then preserves this data across power and reset events. 
Supported subcommands include those shown in the table below. Reference the 
ATA-8 specification for subcommand detail.