Ultimate Technology 600 POS Manuel D’Utilisation

Page de 81
  
 
Series 600 POS Keyboard 
 
 
 
 
23
  
 
 
Table 2.  Local Mode Programming Instructions 
* = Default Settings 
Function Code(s) 
Operation  
 
Normal Indication 
 
 
Remarks 
 
38 
39 
40 
41 
42 
43 
Keyswitch 
Position 1 
MAKE (38) 
 
Keyswitch 
Position 1 
BREAK (39) 
 
Keyswitch 
Position 2 
MAKE (40) 
 
Keyswitch 
Position 2 
BREAK (41) 
 
Keyswitch 
Position 3 
MAKE (42) 
 
Keyswitch 
Position 3 
BREAK (43) 
 
1.  Swipe Program Card.  While in programming mode, at the Series 600 Keyboard 
numeric keypad, enter applicable Function Code 38, 39, 40, 21, 42, or 43
LED (2) flashes.  
2.  At the auxiliary keyboard, type the desired MAKE or BREAK key sequence shown 
below and/or desired key sequence.  Note that the maximum number of key codes is 
limited to 24 – this is equivalent to approximately 12 key strokes. 
 
If the Series 600 Keyboard beeps and 
LED (2) turns off while entering key 
codes at the auxiliary keyboard, you 
have exceeded 24 key codes.  Repeat 
steps 1 and 2. 
 
3.  At the Series 600 Keyboard, press ENTER
LED (2) turns off. 
4.  Program the next function code or exit programming mode by entering  99 on Series 
600 Keyboard numeric keypad or by swiping the Program Card. 
 
 
44 
Poll 
Keyswitch 
 
1.  Swipe Program Card.  While in programming mode, at the Series 600 Keyboard 
numeric keypad, enter Function Code 44
LED (2) turns on. 
2.  At Series 600 Keyboard numeric keypad, enter the applicable number (0 or 1) to 
select polling method per list below. 
 
0 = Send on change or transition 
1 = Send only with poll command B7 
 
 
   LED (2) turns off. 
 
3.  Program the next function code or exit programming mode by entering 99 on Series 
600 Keyboard numeric keypad or by swiping the Program Card.