Ultimate Technology 600 POS Manuel D’Utilisation
Series 600 POS Keyboard
43
Table 5. Remote Programming Mode Commands
OP CODE
(HEX)
MNEMONIC/DESCRIPTION
COMMAND/ACKNOWLEDGEMENT
A2
SNDDLY
Determines rate of delay in milliseconds
for sending macros. This command used
when interfacing with slow systems.
for sending macros. This command used
when interfacing with slow systems.
COMMAND:
A2CxDx<CR>
A2
= Op Code
Cx
= hex value for low nibble
Dx
= hex value for high nibble
Range = 00 - FF; Where 00 is no delay
and each increment in
and each increment in
count equals 10 mS
<CR>
= terminate command (0D hex)
ACKNOWLEDGEMENT: NONE
A3
COMMP
Communications setup for selecting ports,
baud rate, word length, stop bits, parity,
and method of handshaking.
COMMAND:
A3Pbbbbbwsph<CR>
A3
= Op Code
P
= destination port for load
bbbbb
= baud rate
W
= word length 7 or 8 bits
s
= number of stop bits 1 or 2
p
= parity odd, even, or none
h
= handshaking
<CR>
= terminate command (0D hex)
Port:
0 = main; 1 = AUX
Baud rate:
00300, 00600, 01200,
02400, 04800, 09600,
19200, 38400, 57600
Word length:
7 or 8
Stop bits:
1 or 2
Parity:
O = odd, E = even, N = none
Handshaking:
H = CTS/RTS, S = XON/XOFF,
B = both, N = none
ACKNOWLEDGEMENT: NONE