Ultimate Technology 500 POS Manuel D’Utilisation

Page de 80
  
 
 
 
EXTERNAL CONNECTIONS 
 
As required by the hardware configuration, connect the keyboard to its host computer and other 
peripheral devices as shown in Figures 2 and 3.  Note that the specific use for each connector on 
the keyboard is marked adjacent to each connector.  Depending on the make and model of the 
user's equipment, the following cables and/or adapters may need to be supplied by the user to 
complete the installation: 
 
    Standard 6-foot cable, 6-Pin Modular to 6-Pin Modular - UTC Part No. CAB20137 or equivalent  
 
    Keyboard adapter 2-Inch, 5 Pin DIN Male to 6-Pin Mini DIN Female - UTC Part No.900-0839 or equivalent 
 
    Keyboard adapter 12-Inch, 5 Pin DIN Female to 6 Pin Mini Din Male - UTC Part No. 901-5009A or equivalent
 
 
DRAWER JUMPER CONNECTIONS (PRINTER FIRED) 
 
As shown on Figure 3, the Series 500 Keyboard has two status cash drawer ports. Each port is 
selectable by use of the jumper connector located next to the MAIN keyboard connector.  This 
jumper connector is used to make the keyboard compatible with the different printer and cash 
drawer connections required by various manufacturers. 
 
Jumper pin set A and B is used with cash drawer 1: pin set C and D is used with cash drawer 2.  
Installing the jumper on the B (drawer 1) and D (drawer 2) side of the connector causes the status 
signal from the cash drawer to be applied on pin 2 of the related cash drawer port.  Installing the 
jumper on the A (drawer 1) and C (drawer 2) side of the connector causes the status signal from 
the cash drawer to be applied on pin 6 of the related cash drawer port which allows pin 2 to be 
used to open the drawer.  Shown below are the pin connections for the cash drawer ports for each 
position of jumper.  Identified by an "X" are the jumper setting used with typical Epson and Ithaca 
Peripheral devices.   
 
PRINTER 1, 2 PINOUTS 
DRIVER 1, 2 
DRAWER 1, 2 
JUMPER ON A OR C SIDE 
DRAWER 1, 2 
JUMPER ON B OR D SIDE 
1 - SOLENOID GND 
1 - SOLENOID GND 
1 - SOLENOID GND 
2 - SOLENOID GND/STATUS + 
2 - SOLENOID GND 
2 - STATUS + 
3 - STATUS GND 
3 - STATUS GND 
3 - STATUS GND 
4 - SOLENOID + 
4 - SOLENOID + 
4 - SOLENOID + 
5 - SOLENOID GND 
5 - SOLENOID GND 
5 - SOLENOID GND 
6 - NO CONNECTION 
6 - STATUS + 
6 - STATUS + 
EPSON 
 
ITHACA PERIPHERALS SERIES 
50,60 
 
X