Table 5.  Remote Programming Mode Commands - Continued 
OP 
CODE 
(HEX) 
MNEMONIC/DESCRIPTION 
COMMAND/ACKNOWLEDGEMENT 
AF 
COMMENT 
 
Use when notes or comments are 
to be placed in the download file.  
All data is ignored up to the 
carriage return <CR>.  
COMMAND: AFxxxx-xxxx<CR> 
 
AF 
= Op Code 
xx 
= Comments  
<CR>  = terminate command (0D hex)   
 
ACKNOWLEDGEMENT:  NONE
 
B0 
LIGHT 
 
Provides on/off control for keyboard 
light emitting diode (LED) 
indicators.  PC mode for NUM and 
CAP Lock lights is default. 
COMMAND: B0Lx<CR> 
 
B0 
= Op Code 
= lamp 
= on/off 
<CR>  = terminate command (0D hex)   
 
 
 
L: 
0, 1, 2, 3, P in ASCII, where 0 = all.  P 
is used for PC emulation of NUM and 
CAPS Lock 
  
x: 
PC mode 
 
1 = on; 0 = off 
 