Symbol Technologies ES3000 Manuel D’Utilisation

Page de 320
Web Management Access
4-29
4.2.22 PoE Determination Flowchart
Power Budget:
Maximum power allowed for powered devices. 170W for the 
ES3000 switch.
Detection Method:
The powered device detection method. Older devices could 
contain a capacitor. If this option is disabled (default), capacitor 
devices are not detected and powered. Newer devices are 
detected regardless if the Detection Method option is enabled 
or disabled.
Power Management Method:
When the power budget is running out as more powered 
devices connected to the system, the system needs an 
algorithm to determine the power service for the next powered 
device. It could potentially deny the service requested of the 
new device or disable current connected devices to provide 
power to the new device. Two options are given to the 
administrator,
·
Deny next port connection, regardless of 
priority
: The switch keeps providing power to current 
connected powered devices and ignores the requests 
of the newly connected device. The priority set up of 
each port is ignored.