Sterling Welder 882.01749.00 Manuel D’Utilisation

Page de 93
882.01749.00  
71 
of 
93 
 
4-3  Removing the “DD” Disc and Cleaning the Dosing Module 
 
Dismantling the Dosing Module 
1.   Switch the control unit “Off” with 
the “On/Off” switch. 
2.  Disconnect the power supply. 
3.  Open the toggle latches on the 
dosing motor. 
4.   Remove the dosing unit from   
            the dosing motor. 
5.  Empty the dosing module. 
6.  Open the profile clamp on the 
dosing hopper. 
7.  Remove the dosing hopper from the dosing module. 
8.  Dismantle the dosing module and remove the shear (D) as described above in 5.2. 
9.  Loosen and remove the two M6 x 30 socket screws (C) on top of the dosing disc (A). 
10. Remove the center M6 x 12 socket screw (B) and replace with an M6 x 30 or 60 screw. 
11. Lift the dosing disc (A) from the 
dosing unit housing (B) by 
tightening this screw. 
12. Clean the shear plate with a 
cotton cloth. 
13. Clean the dosing hopper and the 
dosing disc in soapy water. 
14. The dosing unit housing may also 
be cleaned with a soft cloth, 
keeping liquids out of the 
bearings.