Sterling Water System 2000HG Manuel D’Utilisation

Page de 8
 
IMPORTANT INFORMATION 
 
In the event of the resale of any of the goods, in whatever form, Resellers/Buyers will include 
the following language in a conspicuous place and in a conspicuous manner in a written 
agreement covering such sale: 
 
 
The manufacturer makes no warranty or representations, expressed or implied, 
by operation of law or otherwise, as to the merchantability or fitness for a 
particular purpose of the good sold hereunder.  Buyer acknowledges that it alone 
has determined that the goods purchased hereunder will suitably meet the 
requirements of their intended use.  In no event will manufacturer be liable for 
consequential, incidental or other damages.
     
 
Resellers/Buyers agree to also include this entire document including the warnings above in a 
conspicuous place and in a conspicuous manner in writing to instruct users on the safe usage of 
the product. 
 
This instruction manual should be read together with all other printed information such as 
catalogs, supplied by Sterling Electric. 
 
GENERAL OPERATION 
 
1.  Run the motor, which drives the unit, and check the direction of unit output rotation. Consult 
motor nameplates for instructions to reverse the direction of rotation. 
 
2.  Attaching the load: On direct-coupled installations, check shaft and coupling alignment 
between unit and loading mechanism.  On chain/sprocket and belt/pulley installation, locate 
the sprocket or pulley as close to the oil seal as possible to minimize overhung load.  Check 
to verify that the overhung load does not exceed specifications published in the catalog. 
 
3.  High momentum loads: If coasting to a stop is undesirable, a braking mechanism should be 
provided to the unit output or the driven mechanism. 
 
     CAUTION: The system of connected rotating parts must be free from critical speed, 
torsional or other type vibration, no matter how induced.  The responsibility 
for this system analysis lies with the purchaser of the speed reducer. 
 
INSTALLATION 
 
1.  Mount the unit using grade 5 or higher fasteners. 
 
2.  For shipment, pipe plugs are installed in the unit and a vent plug is packed separately.  After 
mounting the unit in position, remove the appropriate pipe plug and install the vent plug in 
the location shown in the chart under LUBRICATION.  On double reduction units both the 
primary and the secondary must be vented.  Failure to vent the unit can cause premature 
seal wear or loss of seal and oil.  These conditions are not covered by warranty.  Check for 
correct oil level.  Contact the factory for level and vent recommendations on non-standard 
mounting positions. 
 
CAUTION: 
Do not operate the unit without making sure it contains the correct 
amount of oil.  Do not overfill or underfill with oil, or injury to personnel, 
reducer or other equipment may result.