27
         
Network IP Address: 204.15.5.128 
         
Subnet Mask: 255.255.255.224
Click 
6. 
Apply.
The above Trusted Networks will limit access by Users and the Adminis-
trator, to the ECS0016 serial ports and network attached hosts, however 
they do not restrict access by the Administrator to the ECS0016 console 
server itself. To change the default settings for this access, you will need 
to edit the IP tables rules (as described in the 
Advanced section).
Serial Port Cascading
Cascaded Ports enables you to cluster distributed console servers so a 
large number of serial ports (up to 1000) can be configured and accessed 
through one IP address and managed through the one Management Con-
sole. One console server, the Master, controls other console servers as 
Slave units and all the serial ports on the Slave units appear as if they are 
part of the Master. 
ECS0016 clustering connects each Slave to the Master with an SSH con-
nection. This is done using public key authentication so the Master can 
access each Slave using the SSH key pair (rather than using passwords). 
This ensures secure authenticated communications between Master and 
Slaves enabling the Slave console server units to be distributed locally on 
a LAN or remotely around the world. 
To set up public key authentication you must first upload your RSA or 
DSA key pair into the Master console server.  Please note: If you do not 
already have RSA or DSA key pair you will need to create a key pair us-
ing ssh keygen, PuTTYgen or a similar tool as detailed in 
xxxxxxxxxx
Select 
1. 
System: Administration on Master’s Management Console
Browse to the location you have stored RSA (or DSA) Public Key and  
2. 
  upload it to SSH RSA (DSA) Public Key 
Browse to the stored RSA (or DSA) Private Key and upload it to SSH  
3. 
  RSA (DSA) Private Key 
Click 
4. 
Apply