Sony Ericsson GR64 Manuel D’Utilisation

Page de 91
 
LZT 123 1834 
63
 
 
 
 
Signal 
Mode 
Value 
 
Minimum input voltage 
2.5 
Active High 
Maximum input voltage 
12.0 
SERVICE 
Inactive Low 
Maximum input voltage 
0.8 
 
 
There are two methods for updating the firmware in the GR64: 
Sony Ericsson Emma III and Updater.  The Emma III system is a web 
based tool that accesses a Sony Ericsson server from which signed 
software can be downloaded.  The Updater is a local application 
that downloads a signed image provided by SEMC.   
 
5.13 Buzzer 
Pin 
Name 
Direction 
Function 
31 BUZZER 
Output  Buzzer 
Output 
Connecting the BUZZER signal to an inverting transistor-buffer followed by a 
piezoelectric transducer enables the wireless modem to play pre-programmed 
melodies or sounds. 
5.14  LED 
Pin 
Name 
Direction 
Function 
33 LED 
Output  LED 
control 
signal 
The LED interface is intended to operate a status LED, which can be programmed on 
and off, or for a particular blink sequence.  The LED signal is derived from a standard 
GPIO and does not have sufficient drive capability to operate an LED directly, so it 
requires the user to implement some form of transistor circuit.  A recommended 
implementation is shown below. 
NOTE