72
 
 
 
 
 
Figure 5.20-1  VRTC connection 
 
5.20.2 RTC Alarm (ALARM) 
Pin 
Name 
 Direction 
Function 
50 
ALARM Output 
RTC 
Alarm 
 
The Alarm output is logic output from the module which is supplied from the RTC 
circuitry  block.    This  block  is  in  turn  supplied either from the main supply of the 
module or from a backup battery if the main supply is not available. 
5.20.2.1 
 ALARM Output from the Module 
The ALARM time is set by the use of an AT-command.  The output is normally at 
VRTC level and will go low for one second when the ALARM becomes active.  
Since the VRTC interface is operable down to 1.1V, transistor circuitry must be used 
on the host side.  It is recommended that integrators use an FET to minimize current 
consumption.  If a suitable FET, operating at the low voltage necessary, cannot be 
found then bi-polar must be used.  The resistors shall be kept as high impedance as 
possible to minimize current consumption.