Simrad SIMRAD HS50 Manuel D’Utilisation

Page de 63
Simrad HS50 Heading Sensor 
20221081 / F 
Processing unit 
Enclosure material: .......................................Anodized aluminum 
Enclosure protection: ............................................................. IP44 
Operating temperature range: ................0 to +55ºC (32 to 131°F) 
Storage temperature range: ................. -20 to +60ºC (-4 to 140°F) 
Safe distance to compass: ........................................ 0.2 m (0.7 ft) 
2.8  Cable 
Processing unit to sensor unit cable 
Type: ......................................................2x2x0.5 mm
with shield 
Maximum length:................................................... 100 m (328 ft) 
Diameter: ..............................................................10 mm (0.4 in.) 
Flame retardation:.....................................................IEC 332-3/A 
2.9  Interface 
Configuration:....... Display unit connected to the Processing unit 
Data outputs:........................................Three RS-232 serial lines, 
Three RS-422 serial lines, 
Ethernet UDP/IP 
Data inputs:.................... One RS-232 and one RS-422 serial line 
DGPS corrections: ..... RTCM 104 version 2.2 and SAPOS
®
 EPS 
Baud rate:...........................................................Max. 38.4 kBaud 
HDT, ROT, GGA and GLL data update rates:.......... Up to 20 Hz 
HDT, ROT, GGA and GLL data delay:...............Less than 50 ms 
ZDA and VTG data update rate:....................................Max 1 Hz 
VTG data delay:......................................................... Max 1.5 sec 
ZDA data delay:..................................................................... 1 ms 
 
Data output formats: 
•  NMEA 0183 ZDA, GGA, GLL, VTG, HDT, ROT, GSA, 
GRS and proprietary messages PSXN,20. The PSXN,20 
message include position, height and heading quality 
information 
•  RD Instrument ADCP proprietary NMEA format, "PRDID". 
•  Radar clock data