Simrad SIMRAD HS50 Manuel D’Utilisation

Page de 63
Simrad HS50 Heading Sensor 
28 
20221081 / F 
Ethernet 
The Processing unit can output data on Ethernet from terminal 
J60. In the Ethernet submenu the IP address, netmask, IP port 
number and output format have to be specified. For the NMEA 
format the messages GGA, GLL, VTG, HDT, ROT and RRE are 
included. 
 
IP Address
Default setting: 010 000 021 030. 
IP Netmast
Default setting: 255 255 255 000. 
Format
Format on Ethernet line. The following 
selections are available: NMEA and None
WARNING! 
If “None” is selected as output format, no data will be 
sent to Ethernet line. 
 
Caution! 
A change in IP Address and IP Netmask parameter will not 
take effect before the HS50 is restarted! 
Note! 
The cable to be used has to be a crossed Ethernet cable. 
General 
The  General submenu includes selection of height aiding, 
velocity filtering, Clock data, NMEA id and Datum.