Simrad AP50 Autopilot 
82 
20221032B
 
 
 
VI OLET
B R O W N
P I N K
BL
AC
K
RE
D
WH
IT
E
WH
IT
E
BL
AC
K
RE
D
BLUE ( GND)
Y EL L OW  ( + 5V )
GR EEN  ( WI PER)
N O T E   1
N O T E   2
9
8
1 0
7
6
5
R F 14X U  EL EC T R ON IC  MOD U LE
(V IE W E D   FR OM   B A CK   S ID E )
NOTE 1:   Brown lead normally connected to         . 
                 Move to           to invert the rudder indicator deflection.
NOT E 2:   Normally  connec ted for  +/-45˚  rudder angle  (v iolet, brow n and pink leads are 
                  not connected). For +/-60˚  connect  brown lead to terminal  10, for +/-70˚  connect 
                 pink lead to terminal 10, for +/-90˚  connect violet lead to terminal 10.
                White lead must remain connected.
BR
O
W
N
8
9
8
9
T O
POT .
MET ER
 
Figure 4-9 
RF14XU Internal wiring 
Figure 4-10 shows how to connect the RF14XU Rudder 
Feedback Unit to an AP50 system with 24V autopilot supply.