Use the following table as a guideline. 
Number of RobNet units  Maximum cable length in m (feet) 
1 390 
(1270’) 
2 195 
(640’) 
3 130 
(425’) 
4 95 
(310’) 
5 75 
(245’) 
6 65 
(210’) 
7 55 
(180’) 
8 50 
(165’) 
9 45 
(150’) 
10 40 
(130’) 
If the total length exceeds the recommended length, please 
contact your Simrad distributor on how to arrange the system to 
minimize the voltage drop. 
Examples of interconnecting RobNet units: 
CONTROL
UNIT
JUNCTION
UNIT
NI300X
CONTROL
UNIT
CONTROL
UNIT
JUNCTION
UNIT
NI300X
CONTROL
UNIT
 
Figure 4-21 Interconnecting RobNet Units 
All connectors are crimp-type and can be easily disassembled if 
desired for ease of installation (see Figure 4-22). 
HOW TO REMOVE PINS:
Extraction tool
Pull the wire
Insert tool in slot
 
Figure 4-22  Removing Pin