Signat Powerstream Professional Manuel D’Utilisation

Page de 4
Product
Short
Catalogue
Temperature
BTU
kW loading
Cable Size
Recommended
Reference
Code
Number
Range °C
Output
@ 230-240V
Guide
Fuse Rating
Powerstream Professional 2kW
RFB2
45670202
30 - 80
6830
1.8 - 2
1.5mm
2
13 Amps
Powerstream Professional 4kW
RFB4
45670204
30 - 80
13660
3.7 - 4
2.5/4mm
2
20 Amps
Powerstream Professional 6kW
RFB6
45670206
30 - 80
20490
5.5 - 6
4mm
2
30 Amps
Powerstream Professional 7.5kW
RFB75
45670207
30 - 80
25613
6.9 - 7.5
4/6mm
2
35-40 Amps
Powerstream Professional 9kW
RFB9
45670209
30 - 80
30735
8.3 - 9
6/10mm
2
40-45 Amps
Powerstream Professional 10.5kW
RFB105
45670210
30 - 80
35860
9.6 - 10.5
6/10mm
2
45 Amps
Powerstream Professional 12kW
RFB12
45670212
30 - 80
40980
11 - 12
10mm
2
50
Key Features
Specifier
7 power options (2kW - 12kW) for different 
applications
Compact design fits in most spaces (including 
kitchen cupboards)
Solid state technology for long life
Min/max control adjusts the water temperature 
output from the boiler
No moving parts, maximum reliability
Minimal service and maintenance costs
Suitable for sealed and open vented installations 
and with radiators or underfloor heating
Uses standard radiators, programmer, pump, 
room stat and thermostatic radiator valves
No flue and no fuel tanks mean flexible 
installation location and improved safety
Thermostatic temperature range 30°C to 55°C 
(underfloor) or 55°C to 80°C (central heating)
Outer casing white stove-enamelled 
corrosion-resistant steel
UK manufactured in a BS EN ISO 9001:2000 
registered factory
CE Marked
2 year guarantee
Stockist
Comprehensive technical and aftersales back-up 
service (UK only)
UK manufactured in a BS EN ISO 9001:2000
registered factory
CE Marked
Access to the ‘off gas’ market sector with a 
recognised brand
Installer
Solid state technology for long life
Suitable for sealed and open vented installations 
and with radiators or underfloor heating
Uses standard radiators, programmer, pump, 
room stat and thermostatic radiator valves
No flue and no fuel tanks mean flexible 
installation location and improved safety
Self check circuitry and fault indication
Manually re-settable trips
Unit is set by the Installer for either underfloor 
mode or central heating mode
UK manufactured in a BS EN ISO 9001:2000 
registered factories
CE Marked
2 year guarantee
Homeowner
Silent in operation
The boiler has front panel indication to show 
boiler state, including a power indicator with 
diagnostic facility
Solid state technology for long life
Soft start and zero volt switching to avoid 
power surges
Min/max control adjusts the water temperature 
output from the boiler
No moving parts for long life and 
maximum reliability
Minimal service and maintenance costs
No requirement for annual safety certificate
Control panel
Uses standard radiators, programmer, pump, 
room stat and thermostatic radiator valves
No flue and no fuel tanks mean flexible 
installation location and improved safety
Thermostatic temperature range 30°C to 55°C 
(underfloor) or 55°C to 80°C (central heating)
Outer casing white stove-enamelled 
corrosion-resistant steel
Re-settable trips
CE Marked
2 year guarantee
Technical Product Dimensions (mm)
396
86 
238 
116
69
Outlet
386 
49
Inlet
The Range