Applications Engineering 
 
Appendix A. Troubleshooting Guide 
This section discusses possible problems you may encounter while installing the development tool 
software, USB drivers, or running the HEW debugger and FoUSB Programmer applications. This section 
also discusses the countermeasures and solutions to resolve these problems.  
 
For troubleshooting information on the RF Sniffer Interface and RF Sniffer board, see the RF Sniffer 
User’s Manual. 
 
If, for any reason, you cannot resolve the problem, please contact your Renesas representative for 
assistance. 
A.1 Manual Installation 
 
Before connecting the In-Circuit Debugger to your PC, the driver files (.inf and .sys) and executables must 
be copied to the C:\Renesas\FoUSB directory.  
 
To do this, run FoUSB_Vx.xx.exe in the \Tools\FoUSB directory of the CD. After the FoUSB 
Programmer install, assuming the default directory was used, a C:\Renesas\FoUSB subfolder should 
have been created. The Windows USB drivers can be found under the USB Drivers folder, i.e. 
fousb.inf, fousb.sys (driver files to run FoUSB Programmer), usbmon.inf, and usbmon.sys 
(driver files to run HEW).  
 
A.2 USB Driver Problems 
 
This part discusses how to fix common problems that may occur with USB driver installation. The most 
common problem is that Windows did not properly install the USB drivers, so that the ICD is not 
recognized. An indication of this problem is the faster blink rate of the ICD’s yellow Status LED of about 2-
3 times per second. When the driver is installed properly, the yellow Status LED only blinks every second. 
 
Before trying the following steps, try re-starting your PC to see if this resolves the problem. You can check 
the USB Driver status using the Windows Device Manager (Start > Control Panel > System Properties > 
Hardware > Device Manager > Universal Serial Bus controllers). If the “Renesas FoUSB ICD” appears 
under the Universal Serial Bus controllers with no red X or yellow exclamation point, the driver was 
installed properly. 
 
NOTE: If you are using Windows 2000 or XP, you will need Administrator privileges to be able to 
install the drivers

 
For cases where “Renesas FoUSB ICD” appears with a red X or yellow exclamation point in the Windows 
Device Manager, please try the following: 
 
1.  Open the Windows Device Manager (Start > Control Panel > System Properties > Hardware > 
Device Manager > Universal Serial Bus controllers). 
2.  Double-click on ‘Renesas FoUSB ICD’. A Renesas FoUSB ICD Properties dialog box appears. 
3.  Click on the ‘Driver’ tab and click the ‘Update Driver’ button. 
4.  Select ‘Display a list…’ and click on the ‘Have Disk’ button.  
5.  Browse to the C:\Renesas\FoUSB\USB Drivers  directory  and install the usbmon.sys 
driver. 
6.  If this process does not work, please follow the instructions below. 
 