Renesas R61509V Manuel D’Utilisation

Page de 181
R61509V 
        Target 
Spec 
 
Rev. 0.11 April 25, 2008, page 46 of 181  
 
Display Control 2 (R008h) 
 
FP[7:0]: Sets the number of lines for front porch period (a blank period made after the end of display). 
BP[7:0]: Sets the number of lines for back porch period (a blank period made before the beginning of 
display).  
In external display interface operation, a back porch (BP) period starts on the falling edge of the VSYNCX 
signal and the display operation starts after the back porch period.  After the front porch period, a blank 
period continues until next VSYNCX input is detected. 
Table 13  
FP [7:0] 
BP [7:0] 
Number of front porch line
 
Number of back porch line  
8’h00 
Setting inhibited  
Setting inhibited 
8’h01 Setting 
inhibited 
Setting 
inhibited 
8’h02 Setting 
inhibited 
lines 
8’h03 
3 lines  
3 lines 
8’h04 
4 lines 
4 lines 
8’h05 
5 lines 
5 lines 
8’h06 
6 lines 
6 lines 
8’h07 
7 lines 
7 lines 
8’h08 
8 lines 
8 lines 
8’h09 
9 lines 
9 lines 
8’h0A 10 
lines 
10 
lines 
8’h0B 11 
lines 
11 
lines 
8’h0C 12 
lines 
12 
lines 
8’h0D 13 
lines 
13 
lines 
8’h0E 14 
lines 
14 
lines 
8’h0F 15 
lines 
15 
lines 
 
 
 
8’h7F 127 
lines 
127 
lines 
8’h80 128 
lines 
128 
lines 
8’h81 Setting 
inhibited 
Setting 
inhibited 
 
 
 
8’hFF Setting 
inhibited 
Setting 
inhibited 
 
 
 
R/W  RS  IB15 IB14 IB13 IB12 IB11 IB10
IB9
IB8
IB7
IB6
IB5
IB4
IB3  IB2  IB1  IB0 
R/W 1 
FP 
[7] 
FP
[6]
FP 
[5] 
FP 
[4] 
FP
[3]
FP
[2]
FP
[1]
FP
[0]
BP
[7]
BP
[6]
BP
[5]
BP
[4]
BP 
[3] 
BP 
[2] 
BP 
[1] 
BP 
[0] 
Default 
 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0