• 100 volt model ranges from 95 - 105 v
   Default setting is 100 volts.
• 120 volt model ranges from 100 - 120 v
   Default setting is 117 volts.
• 240 volt model ranges from 220 - 240 v
   Default setting is 240 volts.
  (adjustments in 2 volt increments)
As  long  as  the  voltage  to  the  Power  Plant  does 
not  deviate  more  than  10%  below  normal  it  will 
continue  to  output  the  voltage  displayed  on  the 
front panel. 
Wattage produced
This  mode  will  display,  in  real-time,  the  wattage 
the P1000 is generating. The P1000 is capable of 
delivering up to 1000 watts for short amounts of 
time, however if over 1000 watts is drawn for too 
long or peak wattage is too large then the P1000 
will  go  into  protection  mode. The  watt  meter  will 
only  show  the  total  wattage  produced  for  the 
zone labeled Regenerated AC.
Percentage of maximum power output
This  mode  will  display,  in  real-time,  the  percent-
age of total power currently being used by equip-
ment on the Regenerated AC outlets. This reading 
will factor the type of load into the percentage of 
maximum power output. The percentage of maxi-
mum power output is not necessarily proportional 
to  the  wattage  produced,  as  it  will  vary  with  the 
type of load.
It is possible that the display will show over 100% 
for  short  amounts  of  time  during  heavy  current 
draw. This will typically occur during loud or very 
dynamic passages of music or very bright scenes 
in video. The P1000 will not maintain 100% output 
power continuously.
Display Blanking
This  mode  allows  discrete  front  panel  operation 
by blanking the display. The PS logo will continue 
to  illuminate  in  blue  to  indicate  that  the  unit  is 
operational. 
Additional Display Notifications 
HOT! - If the P1000 exceeds safe operating tem-
perature the front panel display will flash “HOT!”. 
The Regenerated AC outlets will stop generating 
AC until the P1000 returns to safe operating tem-
perature. The power should not be disconnected 
at this time. See troubleshooting guide if problem 
persists.
PERCENTAGE  -  If  the  equipment  connected  to 
the  Regenerated  AC  outlets  draws  current  over 
100%  for  more  than  3  seconds,  or  over  200% 
for  any  amount  of  time,  the  display  will  flash 
the  over  current  percentage  (ex.  184%)  and  the 
P1000  will  shut  down.  If  the  behavior  continues 
the load should be reduced. This can be done by 
moving  some  of  the  equipment  powered  by  the 
Regenerated AC outlets to the Filtered AC outlets. 
See troubleshooting guide if problem persists.
SHORT - If the P1000 detects an electrical short 
either  internal  or  external  the  front  panel  display 
will flash “SHORT”. If turning the unit off and back 
on again from the front panel does not correct the 
problem then the power cable should be removed 
and reinserted. See troubleshooting guide if prob-
lem persists.
FAULT - If there is any other type of operational 
error  the  P1000  will  flash  “FAULT”  in  the  dis-
play. The same procedure should be taken as in 
SHORT mode. See troubleshooting guide if prob-
lem persists.
Note About Operation:
In  all  of  these  situations  the  Regenerated  AC  outlets  will 
not  produce  power,  however,  the  Filtered  AC  outlets  will 
continue to pass power. If the P1000 is in display blanking 
mode the above notifications will still be displayed.
6
Setup Display Mode 
There  are  5  additional  parameters  that  you  can 
access in the setup display mode. 
The  setup  display  mode  can  be  activated  by 
pressing  the  Mode  Up  and  Mode  Down  buttons 
simultaneously while powering on the P1000.
Pressing Mode Up/Down will scroll through the 5 
setup parameters. The 4-setup parameters are:
1. Software version  
 
[VER.]
2. Network Address  
 
[N ADR]
3. Network Group    
 
[N GRP]
4. Network Power On/Off    
[N PWR]
5. Reset  
 
 
 
[RESET]
To exit the setup menu at any time, power down 
the P1000 and all changes will be saved.
Software version
This mode will display the current version of the 
P1000  operation  software.  Press  the  Edit  Up/
Down  key  to  display  the  version  number.  This 
mode cannot be edited.
Network Address
If more than one piece of PS Audio equipment is 
used in a system, then each piece connected to 
the PS Bus must have a unique Network Address. 
In this way, each piece of PS Audio equipment can 
easily be recognized and identified in the Network 
Bus. There are 8 possible Addresses (1-8) which 
can  be  selected  by  pressing  the  Edit  Up/Down 
buttons when in the Network Address mode.
If no Network Address is set then the P1000 will 
operate  independently  of  any  other  PS  Audio 
equipment on the PS Bus.
Network Group
It  is  possible  to  assign  the  P1000  to  a  unique 
Network  Group.  There  are  3  possible  groups 
which  can  be  selected  by  pressing  the  Edit  Up/
Down buttons when in the Network Group mode. 
If it is necessary to have more than one Group on 
the PS Bus then, all PS Audio products can exist 
on the same PS Bus yet communicate in separate 
groups.
Network Power
The  Network  Power  setting  will  alter  which  PS 
products  will  be  affected  by  the  power  status  of 
the P1000. It can be set to Power or Global. 
If set to Power, the P1000 will control the power 
status of other PS Audio “power” products on the 
same Network Group. If set to Global, it will con-
trol the power status of all products on that Net-
work Group. The default setting is Power.
Reset 
If at any time it is necessary to reset all of parame-
ters of the P1000 to their default settings, it can be 
done by pressing the Edit Up/Down button twice 
while in RESET mode. See Also the troubleshoot-
ing guide.