ELECTRICAL CONNECTIONS 
 
WARNING- DO NOT APPLY POWER UNTIL TOLD TO DO 
SO. RISK OF SHOCK OR INJURY MAY RESULT! 
 
NOTE: Wiring to operator must use watertight materials in 
accordance with local electric code. See wire gauge/distance 
charts for proper sizing.  Master/Slave installations should have 
SEPARATE power supply wiring or length of wire runs should 
be figured at half that shown on the chart. This unit must be 
grounded in accordance with N.E.C. and local codes. 
Before connecting the operator, use a voltmeter to determine 
that the electrical service is 115V. THIS OPERATOR CANNOT 
BE CONNECTED AT 230 VOLTS. Damage will result which is 
not covered under warranty. 
 
 
 
 
 
L O W       V O L T A G E     W I R E
G A U G E   / D I S T A N C E     C H A R T
2 4   A W G :             U p   t o   1 5 0 '
  2 0   A W G :             1 5 0 '  -   2 0 0 '
                                                2 5 0 '   -   1 , 5 0 0 '
C o n t r o l  w i r i n g   s h o u l d   b e   r u n   a s   t w i s t e d
p a i r s .   D O   N O T   r u n   c o n t r o l   w i r e s   i n   t h e
s a m e   c o n d u i t   a s   p o w e r   w i r e s .   t e l e p h o n e
w i r e s ,   o r   l o o p   d e t e c t o r   l e a d s .
1 8   A W G :
 
 
 
 
Line 
Voltage 
HP 
14 
AWG 
12 
AWG 
10 
AWG
AWG
 
AWG
 
115 VAC 1/2 150’ 250’ 400’ 500’ 650’
 
22 
1.  Be sure power switches at source and operator are 
OFF. 
 
2.  Connect incoming power lines and ground wire as 
shown below. 
 
Hot leg (black) to BLACK; Neutral (white) to White: 
Ground to Ground Screw. 
 
 
Incoming
Power
115V - 1Ø
Operator
BLK
BLK
WHT
WHT
GND
GND
Inside Power Box,
Connect As Shown
Power
Switch
Power
Box
   
 
NOTE: In order to properly run and check the operator 
at various stages during the setup procedure, it is 
suggested that a three button control station be 
connected at this time.  See page 24.