Line Service Commands
Set Modbus-Slave Line
Description Sets the Modbus slave parameters for the line. 
User Level Admin
Syntax
Options
crlf
protocol
uid-range
 
Set Modbus-Master Line
 
<IP_address>
Specify the IP address of the remote host that is receiving the vmodem connection.
<TCP_port>
Specify the TCP port that the remote host is lisening on for the vmodem connection.
delete
Deletes the specified entry from the phone number table.
set modbus-slave line .|<number>|* [crlf on|off]  
[protocol rtu|ascii] [uid-range <uid_range>] 
When 
Modbus/ASCII
 is selected, adds a CR/LF to the end of the transmission; most 
Modbus devices require this option. The default is 
On
.
Specify the protocol that is used between the Modbus Master(s) and Modbus Slave(s), 
either RTU or ASCII.
You can specify a range of UIDs (1-247), in addition to individual UIDs. The format is 
comma delimited; for example, 2-35, 50, 100-103.
Description Sets the Modbus master parameters for the line.
User Level Admin
Syntax
set modbus-master line .|<number>|* [crlf on|off]  
[protocol rtu|ascii]  
[[entry <number> [port <port>] [protocol udp|tcp]  
 [range-mode gateway|host] [slave-ip <IP_address>]  
 [uid-range <start_uid> <end_uid>]] 
Options
crlf
When 
Modbus/ASCII
 is selected, adds a CR/LF to the end of the transmission; most 
Modbus devices require this option. The default is 
On
.
protocol
Specify the protocol that is used between the Modbus Master(s) and Modbus Slave(s), 
either RTU or ASCII.
entry
You can specify up to 16 Modbus Slave Remote IP Mapping entries (the UIDs must not 
overlap).
port
The destination port of the remote Modbus TCP Slave that the IOLAN will connect to.