Pentair spa heater Manuel D’Utilisation

Page de 40
P/N 471048
                     Rev. E  2-7-01
22
SPA
COM
POOL
TPROBE
OUT
RETURN
24 VAC
HILMT
IGNITION MOD
EXT SWITCH 
THERMOSTAT CIRCUIT BOARD
JUMPER REQUIRED IF NO 2 WIRE REMOTE SWITCH
POOL/OFF/SPA
FRONT PANEL
THERMOSTAT SELECT SWITCH
TFUSE
VALVE
PRESS
SPA
COM
POOL
TPROBE
OUT
RETURN
24 VAC
HILMT
IGNITION MOD
EXT SWITCH 
THERMOSTAT CIRCUIT BOARD
JUMPER REQUIRED IF NO 2 WIRE REMOTE SWITCH
POOL/
OFF/SPA
FRONT PANEL
THERMOSTAT SELECT SWITCH
TFUSE
VALVE
REMOTE POOL/OFF/SPA
THERMOSTAT SELECT SWITCH
PRESS
WHT
GAS VALVE
ORN
WHT
HI-LIMIT
OFF
SPA 
WHT
WHT
SHUT-OFF
SAFETY
SWITCH
PRESS
WHT
POOL 
MINIMAX WIRING DIAGRAM
(MILLIVOLT) DUAL THERM
(HONEYWELL ELECTRONIC)
PILOT
GENERATOR
 THERMAL
 CUT-OFF
TH
PP
TH/PP
POT 1
THERMOSTAT BOARD
POT 2
TH/PP
PP
POT
SENSOR
SEN
TH
WHT
IF ORIGINAL FACTORY WIRING MUST BE REPLACED,
INSTALLER MUST SUPPLY UL OR CSA (IF CANADA)
APPROVED WIRE, 18 GAUGE, 600V, 105 C˚ TEMPERATURE RATING.
THERMAL FUSE WIRING MUST BE REPLACED WITH
UL OR CSA (IF CANADA) APPROVED WIRE,
18 GAUGE, 600V, 125 C˚ TEMPERATURE RATING.
INTERCONNECTING WIRING TO APPLIANCE MUST
CONFORM TO THE NATIONAL ELECTRICAL
CODE OR SUPERCEDING LOCAL (WIRING) CODES.
WHT
RED
Installation (contd.)
NOTE: When connecting a remote control to the MiniMax Plus, you must install the low voltage
thermostat wires in separate conduit from ANY line voltage wires. Failure to follow these
instructions will cause the thermostat relay to react erratically.
.
REMOTE SWITCH DUAL THERM IID ONLY
Figure 28.
Figure 29.
Figure 27.
3 Wire  Remote
2 Wire  Remote
MiniMax Plus Millivolt Wiring Diagram
After 1-15-01