Trilogy Touch Technology Trilogy Commander Digital Intercom 9 Manuel D’Utilisation

Page de 81
Commander Installation Guide 
 
 
 
 
 
 
 
 
 
 
 
Trilogy Communications Limited 
Page 59 of 81 
Issue 9 
 
7.4.1.2  ISDN Interface RJ45 Connector  
 
RJ45 Fixed Socket 
Pin 1  
Not connected 
Pin 2 
Not connected 
Pin 3 
Tx to network A/Rx from terminal A 
Pin 4 
Rx from network A/Tx to terminal A 
Pin 5 
Rx from network B/Tx terminal B 
Pin 6 
Tx to network B/Rx from terminal B 
Pin 7 
Not connected  
Pin 8 
Not connected 
 
7.4.1.3  Com Port 
D9, not yet supported, for future development. 
7.4.1.4  Remote Ports 
Each input is the cathode of the LED on an opto-isolator. The anode is connected through a 
470R resistor to +5VDC. Therefore to activate a control input, short the pin to ground, i.e. pin 
10. Each output is the open collector of a ULN2003 driver chip. Therefore connect the pin 
through load to +5VDC. 
7.4.1.5  RJ45 
This is the ISDN 2 connector. This must only be connected to an approved ISDN 2 
connection or serious damage may occur.