Toro EC-XTRA Landscape Timer, 6-Zone (53794) Guide De Montage

Page de 44
Connecting a Pump Start Relay
CAUTION: To prevent timer damage, ensure the 
24 VAC pump relay current draw does not exceed 
0.30 Amps. Do not connect the timer directly to the 
pump starter. 
1.  Route a wire pair from the pump relay into the timer 
housing.
2.  Connect one wire to the terminal labeled COM (10). 
Connect the remaining wire to the terminal labeled 
PUMP/MV (9) as shown below.
CAUTION: To prevent pump damage due to  
back pressure, connect a jumper wire from any 
unused zone terminal to a zone terminal with a valve 
connected. 
Note: 
Refer to “Pump Control” section on page 29 for 
important pump control information.
Connecting the Plug-In Transformer
CAUTION:
 Do not plug the transformer into an 
electrical outlet until all of the wiring procedures have 
been completed.
1.  Route the cord from the transformer (13) through the 
small opening provided in the base of the housing as  
shown below.
2.  Connect one transformer cable wire to each terminal 
labeled 24 VAC (8). The wires can be connected to 
either terminal.
Note:
 When power is applied to the timer, the display  
will begin flashing 12:00 
am
. Press any button to halt 
flashing. 

SENSOR
24 VAC
MANUAL
START
ON
NEXT
OFF
8
13
SENSOR
24 VAC
PUMP/MV
COM
MANUAL
START
ON
NEXT
OFF
24 VAC Pump 
Start Relay
10
9
Jumper Wire
Valve Common Wire