   4 STANDARD MEASUREMENT MODE
4.2
Distance Measurement
4.2.1 Setting of the Atmospheric Correction
When setting the atmospheric correction, obtain the correction value by measuring the temperature 
and pressure. 
Setting the atmospheric correction is in the STAR key (
H
4.2.2 Setting of the Correction for Prism Constant
Topcon's prism constant value is 0. Set correction for prism at 0. If the prism is of another manufacture, 
the appropriate constant shall be set beforehand. 
Setting the prism constant value is in the STAR key (
H
4.2.3 Distance Measurement (Continuous Measurement)
Make sure the mode displays angle measurement
.
Operating procedure
Operation
Display
1
Collimate the center of prism.
2
Press [F1](SD) key or [F2]( HD )key.
*1), 2)
[Example] Horizontal distance mode
[F2]
The result are shown *3) ~ *6)
*1)
The following characters will be shown on the 4th line right hand corner of the display to 
represent measurement mode.
F: Fine meas. mode, C: Coarse (1mm) meas. mode, c: Coarse (10mm) meas. mode.
R: Continuous (Repeat) meas. mode , S: Single meas. mode, N: N time meas. mode
*2) When EDM is working, the "* " mark appears in the display. 
*3) The result is shown with buzzer sound.
*4) Measurement may repeat automatically if the result is affected by shimmer etc..
*5) To change single measuring, press [F1](MEAS) key.
*6) To return to the angle measurement mode, press [F3](VH) key.
 V :  90
°10'20"   
 HR: 120
°30'40"      
                    
                     
 
SD  HD  NEZ  0SET  HOLD  P1
 V :  90
°10'20"   
 HR: 120
°30'40"  PSM   0.0  
 HD:          <  PPM   0.0
 VD:             (m) *F.R
MEAS  MODE  VH   SD  NEZ  P1
 V :  90
°10'20"   
 HR: 120
°30'40"   PSM   0.0 
 HD:      716.661 PPM   0.0
 VD:        4.001   (m)  *F.R 
MEAS  MODE  VH   SD  NEZ  P1