Thecus Technology N8800 Manuel D’Utilisation

Page de 120
Capacity (MB) 
Capacity of the installed hard disks. 
Model 
Model number of the installed hard disks. 
Status 
Status of the installed hard disks. 
Member 
If this is checked, current hard disk is a part of a RAID volume. 
Spare 
If this is checked, current hard disk is designated as a spare for 
a RAID volume. 
Stripe Size 
This sets the stripe size to maximize performance of sequential 
files in a storage volume. Keep the 64K setting unless you 
require a special file storage layout in the storage volume. A 
larger stripe size is better for large files. 
Used Percentage 
The percentage of the RAID volume that will be used to store 
data. 
Apply 
Press this button to configure a file system and create the RAID 
storage volume. 
Remove 
Click to remove the RAID volume. All user data, and iSCSI data 
will be removed. 
Back 
Press this button to exit without saving changes. 
Expand 
Press this button to configure a file system and create the RAID 
storage volume. 
Migration 
Press this button to migrate RAID level. 
Creating a RAID 
To create a RAID volume, follow the steps below: 
 
1.  On the RAID Information screen, click New
 
2.  On the RAID Configuration screen, set the RAID storage space as JBOD
RAID 0RAID 1RAID 5RAID 6, or RAID 10 — see 
 for a detailed description of each. 
 
3.  Specify a RAID ID.  
 
4.  If this RAID volume is meant to be the Master RAID volume, tick the 
Master RAID checkbox. 
 
NOTE 
In a multiple RAID configuration, one RAID volume must be 
designated as the Master RAID volume. The Master RAID volume will 
store all installed modules. If the Master RAID is changed to another 
location (i.e. assigning HDD 2 to be the Master RAID volume after 
HDD 1 had been previously assigned), then all modules must be 
reinstalled. In addition, all system folders that were contained on the 
Master RAID volume will be invisible. Reassigning this volume to be 
the Master RAID will make these folders visible again. 
 
 
 
 
 
 
 
5.  Tick the checkboxes under the “member” heading of the hard disks you 
wish to use to create a RAID.  
 
6.  Specify a stripe size — 64K is the default setting.  
 
7.  Specify the percentage allocated for user data. The remaining space will 
be made available for iSCSI target. 
 
8.  Selected the file system you like to have for this RAID volume.  
 
 
Select ZFS file system while snapshot is needed. It is only one ZFS file 
system allowed to be created per system.  
ZFS file system is only accessible by CIFS/SMB, not for AFP and NFS 
users.  
NOTE 
 
 
 
9.  Press Apply to build the RAID storage volume. 
 
 
 
30