Texas Memory Systems RamSan-325/325c Manuel D’Utilisation

Page de 121
 
 
 
RamSan-325/325c User’s Manual 
 
- 117 - 
Name array-state-notif 
Description  
The disk array state has changed 
Includes 
Message 
 
 
 
Name fc-state-notif 
Description  
A fibre channel controller state has changed 
Includes 
Message 
Device Number 
Disk State: 
-1  notImplemented  This indicates there may be an SNMP reporting 
problem 
 
0  noState 
N/A 
1 error 
N/A 
2  warn 
N/A 
3  good 
The FC controller is working properly. 
 
4  warnHigh 
The FC controller has detected some type of error; 
possibilities include: RX errors, CRC errors, and 
corrected ECC errors. 
 
5  errorHigh 
The FC controller is not functioning correctly; the 
controller has failed or detected uncorrected ECC 
errors. 
 
6  noDevice 
N/A 
7 notMonitored 
N/A 
 
 
 
 
Name lun-change-notif 
Description  
The LUN table has changed 
Includes 
Message 
 
 
 
Name fc-config-change-notif 
Description  
The configuration of a fibre channel controller has changed 
Includes 
Message 
Device Number 
 
 
 
Name system-message-notif 
Description  
A system message 
Includes 