2.7  Placing a CSD Data call (not GPRS) 
Before a data call can be placed, it is recommended to check if the mobile is registered on a network 
(see par. 2.5.3.1) and if the signal strength is enough to ensure that a call can be made. 
2.7.1  Data call device set up 
 
2.7.1.1   Set the device in data mode 
•  Send command  
AT+FCLASS=0<cr>
 
• wait 
for 
OK
 response 
 
TIP: The +FCLASS setting is maintained in memory, so there's no need to repeat this command 
if  +FCLASS setting is not changed. 
 
 
 
2.7.1.2   Set the desired modulation and speed for the connection 
The data connection can be made using different modulations at different speeds.  
This connection mode can be selected with the command +CBST. The syntax for the command is: 
AT+CBST=<mod>,0,<ce> 
These parameters can be selected as seen in the table: 
 
Command 
Modulation 
Speed 
[bps] 
Connection 
Element 
AT+CBST==0, 0, 1 
Autobauding 
---- 
non transparent 
AT+CBST==1, 0, 1 
V.21 
300 
non transparent 
AT+CBST==2, 0, 1 
V.22 
1200 
non transparent 
AT+CBST==3, 0, 1 
V.23 
1200/75 
non transparent 
AT+CBST==4, 0, 1 
V.22Bis 
2400 
non transparent 
AT+CBST==6, 0, 1 
V.32 
4800 
non transparent 
AT+CBST==7, 0, 1 
V.32 
9600 
non transparent 
AT+CBST==14, 0, 1 
V.34 
14400 
non transparent 
AT+CBST==65, 0, 1 
V.110 
300 
non transparent 
AT+CBST==66, 0, 1 
V.110 
1200 
non transparent 
AT+CBST==68, 0, 1 
V.110 / X.31 
2400 
non transparent 
AT+CBST==70, 0, 1 
V.110 / X.31 
4800 
non transparent 
AT+CBST==71, 0, 1 
V.110 / X.31 
9600 
non transparent 
AT+CBST==75, 0, 1 
V.110 / X.31 
14400 
non transparent 
AT+CBST==1, 0, 0 
V.21 
300 
transparent 
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved 
 