Taurus Group 60 Manuel D’Utilisation

Page de 83
13  Air Inlet System 
13.1 General 
Description 
The gas turbine combustion process requires a steady and consistent flow of clean air. 
Proper gas turbine inlet air filtration is critical to gas turbine life. Careful consideration 
should be given to selecting the appropriate air filtration system. Solar offers several air 
filtration systems that conform to a broad range of operating requirements. For 
unenclosed packages, the turbine air inlet can be mounted on the right-hand or left-hand 
side of the package in a vertical or 45-degree angle to vertical position. For enclosed 
packages, the air inlet must be in the vertical position
.
 Figure 24 shows typical Taurus 60 
inlet systems and support structures. 
13.1.1  Prefilter and Barrier Inlet Air Filter 
The prefilter and barrier inlet air filter system is suitable for moderate environments. This 
system features vertical moisture eliminators, prefilter elements, and high efficiency 
barrier filters. Access doors are provided in the filter housing for servicing. A weather 
hood and insect screens are available as options. The filter house has a back outlet and 
requires ducting and a support frame. 
 
Figure 24. Typical Enclosed Taurus 60 Package with Exhaust and Inlet Systems 
© 2009 Solar Turbines Incorporated. All rights reserved. 
TPS60CSMD/309