Adding and updating gateways 
You can configure the Codian IP VCR with one or more H.323 gateways: 
• 
To add an H.323 gateway, go to 
Gateways > Add new H.323 gateway
. After entering the settings described 
below, click 
Add H.323 gateway
.  
• 
To update an existing H.323 gateway, go to 
Gateways
 and click on a gateway name. After updating the settings 
described below, click 
Update H.323 gateway
.  
Field 
Field description 
More information 
Name 
The descriptive name of the gateway.  
All gateways must have a unique name.  
Address 
The IP address or host name of the gateway. 
  
Motion / 
sharpness 
trade off 
Choose whether to use the unit-wide setting for 
motion/sharpness trade off, or configure an 
individual setting for this gateway. Choose from:  
• 
Use unit-wide setting: this is the default 
value. In this case, connections to the 
gateway will use the motion/sharpness 
tradeoff setting from the 
Settings > 
Connections
 page 
• 
Favor motion: the IP VCR will try and use a 
high frame rate. That is, the IP VCR will 
strongly favor a resolution of at least 25 
frames per second 
• 
Favor sharpness: the IP VCR will use the 
highest resolution that is appropriate for 
what is being viewed 
• 
Balanced: the IP VCR will select settings 
that balance resolution and frame rate 
(where the frame rate will not be less than 
12 frames per second) 
The settings for motion (frames per second) and 
sharpness (frame size or resolution) are negotiated 
between the endpoint and the IP VCR. This setting 
controls how the IP VCR will negotiate the settings 
to be used with this endpoint. 
Preferred 
bandwidth 
from IP VCR  
The network capacity (measured in bits per second) 
used by the media channels established by the IP 
VCR to a single participant. 
  
Preferred 
bandwidth to 
IP VCR  
Sets the bandwidth that the endpoint will advertise 
to the IP VCR when it calls it.