To configure SIP settings on the MCU, go to 
To allow conference participants with SIP endpoints to connect to the MCU by dialing a directory number rather 
than an IP address, you must configure a SIP registrar. The settings on this page control the MCU's interaction with 
the SIP registrar and with SIP endpoints.  
A SIP call will select the audio and video codecs to use from the set of those both allowed on the 
 page and supported by SIP, unless the call is with an endpoint configured with a Custom codec (refer to 
 for more information).  
Refer to this table for assistance configuring the SIP settings. After making any configuration changes, click 
.   
Specifies the level of SIP registration for the 
MCU. 
Can be set to:  
 
No registration: The MCU will not 
register with the SIP registrar. This 
means that a user with a SIP endpoint 
can only connect to the MCU by dialing 
its IP address or hostname  
 
Register MCU only: Enables conference 
participants to dial in to the auto 
attendant of the MCU  
 
Allow conference registration: Enables 
conference participants to dial directly in 
to conferences. For this to work, you 
must configure the SIP registrar with 
conference IDs 
Identifies the network address of the SIP registrar 
to which MCU registrations should be made. 
This can be specified either as a host name or as 
an IP address. This field will have no effect if 
 is set to No registration
Choose between:  
 
Standard SIP: for non-Microsoft SIP 
registrars 
 
Microsoft OCS/LCS: for Microsoft SIP 
registrars 
Your choice is dependent on the type of SIP 
registrar you are using. 
If you are using Microsoft OCS or LCS, you will 
also need to configure the OCS or LCS to 
recognize the IP address of the MCU and treat it 
as authenticated.  
This field will have no effect if 
 is set to No registration
Select this option to force the MCU to present its 
local certificate when registering with the SIP 
registrar.  
Often, the SIP registrar will not require the local 
certificate from the MCU. Only select this option 
if your environment dictates that the SIP registrar 
must receive the local certificate.  
The login name for the MCU on the SIP registrar.  You need to configure the SIP registrar with 
details of the devices that will register with it and 
create a login for each device.