Orbit Manufacturing ORBIT 2000 Manuel D’Utilisation
Page 8 - 4
Maintenance
© GBC Films Group January 2001
Orbit™ 2000 Operation and Maintenance Manual
– The voltage measured between the terminal PE and the test points may not exceed
U =3.3V
for
S= 1.o square millimeters
U = 2.6V
for
S= 1.5 sq. millimeters
U = 1.9V
for
S = 2.5 sq. millimeters
Where U
is the largest drop in voltage and
S
is the smallest effective diameter of the protective conductor in the
tested branch of the protective circuit.
tested branch of the protective circuit.
– The number of measurements of the protective circuit link is given by the requirements
of particular regulations and standards valid in the user’s country.
of particular regulations and standards valid in the user’s country.
– MAIN DRIVE AND FEED TABLE GEAR DRIVE
– Running in
- 300 hrs
-oil PP 90 H
– Normal operation
- 400 hrs
-oil PP 90 H
In case of higher demands the ecologically acceptable oil TOP-BLEND may be used. TOP-BLEND
allows for up to 10.000 operation hours between changes.
allows for up to 10.000 operation hours between changes.
– VARIATOR
– Running in
- 10.000 hrs
- oil OTK 8 to 10
– Normal operation
- 10.000 hrs
- oil OTK 8 to 10