Orbit Manufacturing ORBIT 2000 Manuel D’Utilisation

Page de 139
Page 8 - 4
Maintenance
 © GBC Films Group January 2001
Orbit™ 2000 Operation and Maintenance  Manual
– The voltage measured between the terminal PE and the test points may not exceed
U =3.3V
for
S= 1.o square millimeters
U = 2.6V
for
S= 1.5 sq. millimeters
U = 1.9V
for
S = 2.5 sq. millimeters
Where U
is the largest drop in voltage and
S
is the smallest effective diameter of the protective conductor in the
tested branch of the protective circuit.
– The number of measurements of the protective circuit link is given by the requirements
    of particular regulations and standards valid in the user’s country.
– MAIN DRIVE AND FEED TABLE GEAR DRIVE
– Running in
- 300 hrs
-oil PP 90 H
– Normal operation
- 400 hrs
-oil PP 90 H
In case of higher demands the ecologically acceptable oil TOP-BLEND may be used. TOP-BLEND
allows for up to 10.000 operation hours between changes.
– VARIATOR
– Running in
- 10.000 hrs
  - oil OTK  8 to 10
– Normal operation
- 10.000 hrs
  - oil OTK  8 to 10