5700 Step Top Wood Stove Series ACC
7. 
Snap Disc Location
If you fi nd the blower coming on and off at undesirable 
temperatures, relocate the snap disc to another location 
in  the  designated  zone  on  the  back  of  the  appliance.  
Figure  15.2.    There  is  a  manual  over-ride  switch  to 
deactivate  the  snap  disc,  if  necessary.    See  page  45 
for location of over-ride switch.
N.  Blower Operating Instructions
Figure 15.1 
Figure 15.3
O.  Clear Space
•  Do NOT place combustible objects within 4 ft (1.2 m) of 
the front of appliance. See Figure 15.3.
WARNING! Do NOT place combustible objects in front 
of the appliance. High temperatures may ignite clothing, 
furniture or draperies.
•  Mantel - avoid placing candles and other heat-sensitive 
objects  on  mantel  or  hearth.  Heat  may  damage  these 
objects.
1. Initial (cold) startup:  
Open both controls fully by rais-
ing the Burn Rate Air Control all the way up until it stops 
and slide the Start-up Air Control back until it stops.  
The 
blower tends to cool the appliance.  Leave the blower off 
until the burn is well established, i.e., 30 minutes.
2. High Burn Setting:  Both controls are open.  Burn Rate 
Air  Control  is  pulled  up  and  the  Start-up Air  Control  is 
fully pushed in.  Blower may remain on.
3.  Medium  or  Medium  High  Burn  Setting*:    Burn  Rate 
Air Control is closed then opened to 1 inch to fully open.  
Blower may remain on.
4.  Medium Low Burn Setting*:  Burn Rate Air Control is 
closed then opened to 1/4 inch to 1/2 inch.   Leave the 
blower off until the burn is well established, i.e., 30 min-
utes.
5.  Low  Burn  Setting*:    Burn  Rate Air  Control  is  closed.  
Leave the blower off until the burn is well established, i.e., 
30 minutes.
*NOTE:  For burn settings 3 to 5 the Start-up Air Control 
needs to be pushed in (Open) then pulled back to acti-
vate the Automatic Combustion Control (ACC).
NOTE:  For maximum effi ciency and lowest emissions, 
when  operating  the  blower  in  either  the  automatic  or 
manual setting for the low and medium low burn settings 
leave the blower off until the burn is well established, i.e., 
30 minutes
6.  The blower is equipped with a rheostat (speed control).  
The  highest  blower  speed  is  obtained  by  turning  the 
rheostat on, then adjusting back towards “OFF” as far as 
possible without turning the blower off.  For a low blower 
speed,  turn  the  control  knob  clockwise  as  far  as  pos-
sible
NOTE:  If your Quadra-Fire wood appliance is equipped with 
an optional blower, you should follow these guidelines:
Up (Open) 
Down (Closed)
Start-Up Air 
Control
Burn Rate 
Air Control
Push to Open
Pull back to 
activate ACC
Figure 15.2 - Snap Disc Location 
Maintain 4 ft clearance to com-
bustible in front of appliance