Omni Group Step Top Wood Stove 57ST-ACC Manuel D’Utilisation

Page de 52
Page  18
7038-159D
November 28, 2011
R
5700 Step Top Wood Stove Series ACC
D. Appliance Inspection - Routine
•  Frequency: Every 2 months at the same time the chim-
ney and chimney connector are inspected.
•  By: Homeowner
Check for:
•  Cracks in glass  
•  Door handle - smooth cam operation
•  Baffl e and ceramic blanket  correct placement  
• 
Baffl e for warpage 
•  Firebrick for cracks, broken or crumbly
•  Door gasket.  (Dollar bill test).  Place a dollar bill between 
the stove and the door and then shut the door.  If you can 
pull the dollar bill out, replace the door gasket.
•  Glass frame for loose screws
C. Chimney and Chimney Connector 
     Inspection/Cleaning
• 
Frequency:  Every  2  months  during  heating  season  or 
as  recommended  by  a  certifi ed  chimney  sweep;  more 
frequently if chimney exceeds or is under 14-16 ft (4.3-
4.8m). (measured from base of appliance)
• 
By: Certifi ed Chimney Sweep
•  Remove  all  ash  from  the  fi rebox  and  extinguish  all  hot 
embers before disposal.
•  Allow the appliance to cool completely.  
•  Disconnect fl ue pipe or remove baffl e and ceramic blanket 
from  appliance  before  cleaning  chimney.    Otherwise 
residue  can  pile  up  on  top  of  the  baffl e  and  ceramic 
blanket.  (See Baffl e Removal on page 23).
•  Close the door tightly.
•  The  creosote  or  soot  should  be  removed  with  a  brush 
specifi cally designed for the type of chimney in use.
•  Clean out fallen ashes from the fi rebox. 
•  It is also recommended that before each heating season 
the  entire  system  be  professionally  inspected,  cleaned 
and repaired if necessary.  
WARNING! Risk of Fire! Ignited creosote is extremely HOT. 
Prevent creosote buildup
.
WARNING! Risk of Fire!
Do not use chimney cleaners or fl ame colorants in your 
appliance.  It will corrode your pipe.
Creosote - Formation and Need for Removal
• 
When  wood  is  burned  slowly,  it  produces  tar  and  other 
organic vapors, which combine with expelled moisture to 
form creosote.
• 
The  creosote  vapors  condense  in  the  relatively  cool 
chimney fl ue of a slow-burning fi re.
  
• 
As  a  result,  creosote  residue  accumulates  on  the  fl ue 
lining.  When  ignited  this  creosote  makes  an  extremely 
hot fi re.
• 
The chimney and chimney connector shall be inspected  
every two months during the heating season to determine 
when a creosote buildup has occurred.
  If a signifi cant layer 
of creosote has accumulated (3mm or more) it should be 
removed to reduce the risk of a chimney fi re.
E. Soot or Creosote Fire 
Establish a routine for the fuel, wood burner and fi ring tech-
nique.  Check  daily  for  creosote  build-up  until  experience 
shows how often you need to clean to be safe. Be aware that 
the hotter the fi re the less creosote is deposited, and weekly 
cleaning may be necessary in the mild weather even though 
monthly  cleaning  may  be  enough  in  the  coldest  months. 
Contact  your  local  municipal  or  provincial  fi re  authority  for 
information on how to handle a chimney fi re.
In  the  event  of  a  soot  or  creosote  fi re,  close  the  fi rebox 
door, exit the building immediately and contact the proper 
fi re authorities.  
DO NOT under any circumstances re-enter the building.