Omni Group Step Top Wood Stove 57ST-ACC Manuel D’Utilisation

Page de 52
Page  38
7038-159D
November 28, 2011
R
5700 Step Top Wood Stove Series ACC
Figure 38.1 - Thimble Construction
Trim Collar 
Chimney Section 
with 2 inch 
(51mm) 
Clearance to 
Combustibles
Chimney 
Connector 
Fire Clay Flue 
Liner 
with Airspace 
Masonry 
 Chimney 
Wall Band to 
Secure Chimney 
Section 
Wood Studs Used 
for Framing - Spaced 
2 inch (51mm) 
clearance from 
Masonry Chimney
Wall Spacer 
Solid Pack Chimney with Metal Supports 
as a Thimble
Figure 38.2
1.5”
1.0” 
2.0”
2.0”
1.5”
14.0” ID
17.0” OD
ceiling
Minimum18.0” 
NFPA 211
13.5” below ceiling to top 
of opening
1.0”
8.0”
1.5   2x2 framing stud
2.0   min air clearance
1.0   min air clearance
4.5
or top of opening is a min.of 
4.5” below min.clearance 
specified by connector mfg.
Center of Hole
Thimble
C
L
C
L
Wall
Include depth 
of hearth pad
H.  Thimble
Site constructed for masonry chimney installation:
Components
  •    A  minimum  length  of  12  inches  [305mm]  (longer  for 
thicker  walls)  of  solid  insulated  factory-built  chimney 
length  constructed  to  UL  103  Type  HT  6  inch  (152mm) 
inside diameter.  Chimney needs to extend a minimum of 
2 inches (51mm) from the interior wall and a minimum of 
1 inch (25mm) from the exterior wall.
  •  Wall  spacer,  trim  collar  and  wall  band  to  fi t  solid  pack 
chimney selected.
  •  Minimum  8  inch  (203mm)  diameter  clay  liner  section  (if 
not already present in chimney) and refractory mortar.
Instructions:
1.  Open inside wall at proper height for the chimney con-
nector to enter the masonry chimney.  Figure 38.1.
2.  Entry hole to masonry chimney must be lined with an 8 
inch  (203mm)  minimum  diameter  clay  liner,  or  equiva-
lent, secured with refractory mortar.
3.  Construct a 17 inch x 17 inch (432mm x 432mm) outside 
dimension frame from 2 x 2 framing lumber to fi t into wall 
opening.  Inside opening of frame should be no less than 
14 inch x 14 inch (356mm x 356mm).  Figure 38.1.
4.  Attach the wall spacer to the chimney side of the frame.
5.  Nail the frame into the wall opening.  The spacer should 
be on the chimney side.
6.  Insert the section of the solid insulated chimney into the 
outer wall of the masonry chimney.
7.  Tightly secure the length of the solid insulated chimney 
with the wall band to the masonry chimney.
8.  Insert a section of chimney connector into the chimney.  
Make sure it does not protrude past the edge of the clay 
chimney liner inside the chimney.
9.  Seal the end of the chimney connector to the clay liner 
with refractory mortar.
10.  Install trim collar around the sold pack chimney section.
G.  Air Clearances
 •  Masonry chimney clearance must meet NFPA 211 mini-
mum  requirement  of  2  inches  (51mm)  to  sheet  metal 
supports and combustibles.
 •  Minimum of 1 inch (25mm) clearance around the chim-
ney connector.
 •  Top  of  wall  opening  is  a  minimum  of  13-1/2  inches 
(343mm)  from  ceiling  or  4-1/2  inches  (114mm)  below 
minimum  clearance  specifi ed  by  chimney  connector 
manufacturer.  NFPA 211 minimum vertical clearance of 
18 inches (457mm) from chimney connector and ceiling 
or minimum recommended by chimney connector manu-
facturer.  Figure 38.1.