Nortel Networks Circuit Card Manuel D’Utilisation

Page de 908
Page 426 of 906
 NT6D80 MSDL card
SYSTEM DISABLED—FATAL ERROR
Cause: 
The MSDL card encountered a fatal error and cannot recover. 
The exact reason for the fatal error is shown in the MSDL300 error 
message output to the console of TTY when the error occurred.
Action:
Check the MSDL300 message to find out the reason.
Alternatively, display the status of the MSDL, which also indicates 
the cause of the problem, with the 
STAT MSDL x
 command and 
check the information to find the cause of the fatal error.
Allow the system to attempt recovery. If this fails, either by reaching 
a threshold or detecting self-test failure, place the MSDL in the 
manually disabled state with the 
DIS MSDL x
 command and follow 
SYSTEM DISABLED—RECOVERY THRESHOLD
Cause: 
The system attempted autorecovery of the MSDL card more than 
five times within 30 minutes and each time the card was disabled again. 
The system attempts to enable the card again at midnight unless you 
intervene.
Action
:
Place the MSDL card in a manually disabled state with the 
DIS 
MSDL x
 command and follow the steps in “Previously operating 
.