Parameter 10: Line Folding 
Parameter 10 specifies the maximum number of displayable 
ASCII characters the PAD can send as a single line to the local 
DTE before a new line is begun. The displayable ASCII decimal 
characters (32 - 126) are shown in Appendix F. When the 
maximum character number is reached, the PAD inserts a PAD 
format effecter (carriage return and line feed) into the data 
stream being transmitted or echoed to the local DTE device. The 
format effecter advances the local DTE device display to the 
beginning of the next line to continue the display of the data. In 
the event the local DTE device automatically inserts line folding 
when the characters reach the right-most end of the device 
display, parameter 10 should be set to 0. This parameter applies 
to data, PAD command characters, and PAD service signals.
*default
Parameter 11:  Binary Speed of  Local DTE
Parameter 11 reflects the current speed of the local DTE, which 
is set automatically when the terminal adapter receives an AT 
command prefix while in the AT command mode. This is a 
READ ONLY parameter. The speed indicated by parameter 11 
is the same speed indicated by S61. 
Note: The parameter 11 value for the DTE speed does not 
correspond to the same value for S61 for the same DTE speed 
(see S61).
Table 12-16: Line Folding 
Value
Description
0
No line folding *
1 to 255
Number of displayable ASCII characters per line
Table 12-17: DTE Binary Speed
Value
Description
2
300 bits / sec
3
1200 bits / sec
12
2400 bits / sec
13
4800 bits / sec
14
9600 bits / sec
15
19200 bits / sec
16
38400 bits / sec