Northern UTA220/UTA220k Manuel D’Utilisation

Page de 187
13-2
UTA220/UTA220k
Softload
The TA software file contains an ASCII coded “header” which 
can be displayed to verify the software's product and version 
information before initiating the softload. On DOS based PCs, 
this can be accomplished with the “TYPE” command. For 
example, to view the header information of a file called TA.SL, 
enter:
TYPE TA.SL
A typical header might look like this:
METHOD: SOFTLOAD YGMS-1
PRODUCT: ISDN TA
BOARD ID: 4563672
CPU ID: 0
VERSION: 1CPT-D
TA Power-Up Sequence
When the TA is powered up, it tries to execute the current 
active set. The active set is stored in nonvolatile memory and 
is determined by the last swap command.
However, if the active set indicated by the nonvolatile memory 
selection is invalid, the TA will display a PROM ERROR 
message on the LCD and then attempt to execute the alternate 
set of software. This could occur if a softload session is aborted 
or a hardware failure occurs.
If a SELECTED PROM INVALID message appears, the unit 
will still operate, but possibly with an incorrect software set. 
The error message will remain on the LCD for approximately 
three seconds.
To clear the error, download the correct software, and then use 
the swap command to activate it. If this does not resolve the 
problem, the unit may require factory service.
If a FATAL ERROR occurs, the unit cannot operate and 
must be serviced. PROM ERROR messages are shown in 
Table 13-1.
Table 13-1: 
PROM Error Messages 
LCD Message
Description
SELECTED 
PROM INVALID
 The selected PROM is invalid (blank or last softload session 
failed). The TA is overriding the software selection and is 
executing from the alternate software set.
FATAL ERROR 
PROM INVALID
The selected PROM is invalid, and the alternate software 
set is also invalid. Normal operation is not possible.