Northern UTA220/UTA220k Manuel D’Utilisation

Page de 187
13-6
UTA220/UTA220k
Softload
Copy Active Flash:  $Y2=x
The $Y2 command initiates a softload into the alternate 
software set. The source of the softload is the active software 
instead of a downloaded file. This command requires the 
softload password previously set by the %P1 command. If the 
password does not match the unit’s stored password, the TA 
will return an ERROR message.
After verifying the password, the TA begins erasing the Flash 
memory devices for the alternate software set. If the erasure is 
successful, the TA begins programming the alternate Flash 
PROM.
After the data has been transferred, the TA verifies that the 
flash has been programmed correctly. The TA then sends a 
response code (OK or ERROR) to the DTE indicating the 
success or failure of the entire copy.
S59 SOFTLOAD
To help determine the cause of any problems encountered 
during a softload, the TA can return a result code via the S59 
command to indicate the status of the latest softload. The error 
codes (Tables 13-5 and 13-6) indicate the success or reason for 
failure of softload operations. They are not retained after power 
off, reset, or successful swap. S59 is a read-only command, 
and is not stored in nonvolatile memory.
Table 13-5: 
General Softload Error Codes 
Code
Hex
Description
0
00H
Softload not initiated or incomplete
16
10H
Done, OK
128
80H
Bad softload password
193
C1H
YModem-G initial time-out error
194
C2H
YModem-G inter frame time-out error
195
C3H
YModem-G between frame time-out error
196
C4H
YModem-G invalid frame number
197
C5H
YModem-G CRC error
198
C6H
YModem-G invalid file size error
199
C7H
YModem-G premature end of file
200
C8H
YModem-G cancel received (abort)